Skip to Main Content
U.S. flag

An official website of the United States government


Profile Information

Private
242325
3812 Twining Street TOLEDO, OH 43608
.34
11-05974
41.69198674854292 / -83.52809373172158
9
Stimple, Bradley
stimple.brad@epa.gov
440-250-1717


Top of Page


Property Location



Top of Page


Property Progress


Top of Page


CAs Associated with this Property

CA NameCA #StateTypeAnnouncement Year
City of ToledoBF00E02360OHAssessment2018


Top of Page


Assessment Activities at this Property

ActivityEPA FundingStart DateCompletion DateCAAccomplishment Counted?Counted When?
Phase I Environmental Assessment$4,665.0003/12/202008/31/2020City of ToledoYFY21
Phase II Environmental Assessment$58,455.0003/12/202008/31/2020City of ToledoN
Supplemental Assessment$25,005.0003/12/202008/31/2020City of ToledoN
Supplemental Assessment03/08/202105/03/2021City of ToledoN


Is Cleanup Necessary? Yes
EPA Assessment Funding: $88,125.00
Leveraged Funding: $22,170.00
Total Funding: $110,295.00


Top of Page


Climate Adaption and Mitigation - Planning or Assessment

There is no data for Climate Adaption and Mitigation - Planning or Assessment.


Top of Page


Contaminants and Media


Petroleum Products
SVOCs
VOCs
NOT Cleaned up
NOT Cleaned up
NOT Cleaned up
Ground Water
Soil
NOT Cleaned up
NOT Cleaned up

Cleanup Activities

There are no current cleanup activities.


Cleanup/Treatment Implemented: N
Cleanup/Treatement Categories:
Addl Cleanup/Treatment info:
Address of Data Source:
Total ACRES Cleaned Up: .34
Number of Cleanup Jobs Leveraged:
EPA Cleanup Funding:
Leveraged Funding:
Cost Share Funding:
Total Funding:


Top of Page


Climate Adaption and Mitigation - Demolition or Cleanup

There is no data for Climate Adaption and Mitigation - Demolition or Cleanup.


Top of Page


Institutional and Engineering Controls

Yes
Proprietary Controls Government Controls
Issuance of Covenant Not to Sue for this project was received on September 14, 2021.
Yes
09/20/2021
Yes
Cover Technologies (e.g., Capping) Other SSD system is in place
Interim cover of 12" of clay before paved parking lot is constructed in late 2021.
Yes
12/21/2020


Top of Page


Redevelopment and Other Leveraged Accomplishments

Start DateLeveraged FundingCACompletion Date
12/21/2020$18,200.00City of Toledo
12/21/2020$23,000,000.00City of Toledo


Number of Redevelopment Jobs Leveraged:
Actual Acreage of Greenspace Created:
Leveraged Funding:


Top of Page


Climate Adaption and Mitigation - Redevelopment

There is no data for Climate Adaption and Mitigation – Redevelopment


Top of Page


Additional Property Attributes

Based on a review of historical Sanborn Fire Insurance Maps and aerial photographs, a portion of the Property located at 3812 Twining Street has been utilized as a solvent and thinner storage yard between at least 1957 and 1976. The Sanborn Map indicated that materials were stored within steel drums and several storage tanks. Due to the activities associated with the solvents and thinners, impacts to soil vapor and groundwater have occurred from VOCs, SVOCs, TPHs DRO and GRO, and PCBs. Phase II laboratory analytical results showed that multiple COCs were reported above laboratory method detection limits in soils including: metals, TPH, PCBs, VOCs, and SVOCs. Laboratory analytical results for groundwater samples collected during the Phase II activities indicated the presence of VOCs and SVOCs above laboratory method detection limits. Laboratory analytical results for the soil vapor samples indicated the presence of several VOCs above laboratory method detection limits. Based upon the investigation activities completed as described herein, the Property will comply with applicable standards under the Ohio VAP based upon implementation of the following activities at the Property: * the establishment of an institutional control that restricts the Property to commercial/industrial land use as defined in OAC 3745-300-08(C)(2)(c); * the establishment of an institutional control that precludes the use of groundwater at the Property, in accordance with OAC 3745-300-11(C)(2); * an activity and use limitation that restricts occupancy of buildings constructed on the Property until such time that either: (i) a remedy that eliminates potential indoor air vapor intrusion exposures to hazardous substances in excess of applicable standards is installed, operated and maintained as an engineering control under an O&M agreement and plan or (ii) the Certified Professional demonstrates through additional sampling and Property-specific analysis that, based on building design and the Property complies with applicable standards for the vapor intrusion to indoor air exposure pathway without further implementation of remedial activity in accordance with OAC 3745-300-07 (F)(4); * implementation of interim measures in accordance with OAC 3745-300-11(C)(6) until the installation of an asphalt parking area as an engineering control to preclude direct contact with soil through an O&M Plan; and * implementation of an RMP to mitigate unacceptable hazard and risk associated with direct contact with soil and groundwater.
Industry (.34)
Petroleum
ID Number (if Applicable): 21NFA777 Enrolled: 12/28/2020
09/14/2021