Skip to Main Content
U.S. flag

An official website of the United States government


Profile Information

Private
252769
20201 Livernois Ave. DETROIT, MI 48221
.58
16017473-1
42.44238799551613 / -83.14227303636366
13
Mankowski, Craig
Mankowski.Craig@epa.gov
312-886-9493


Top of Page


Property Location



Top of Page


Property Progress


Top of Page


CAs Associated with this Property

CA NameCA #StateTypeAnnouncement Year
County of WayneBF00E02726MIAssessment2019
County of Wayne4B00E03553MIAssessment2023


Top of Page


Assessment Activities at this Property

ActivityEPA FundingStart DateCompletion DateCAAccomplishment Counted?Counted When?
Phase I Environmental Assessment$3,100.0004/08/202206/13/2022County of WayneYFY23
Phase II Environmental Assessment$4,012.5006/09/202209/30/2022County of WayneN
Supplemental Assessment$10,745.0010/06/202411/06/2024County of Wayne


Is Cleanup Necessary? Yes
EPA Assessment Funding: $17,857.50
Leveraged Funding:
Total Funding: $17,857.50


Top of Page


Climate Adaption and Mitigation - Planning or Assessment

There is no data for Climate Adaption and Mitigation - Planning or Assessment.


Top of Page


Contaminants and Media


Asbestos
Lead
NOT Cleaned up
NOT Cleaned up
Building Materials
NOT Cleaned up

Cleanup Activities

There are no current cleanup activities.


Cleanup/Treatment Implemented: N
Cleanup/Treatement Categories:
Addl Cleanup/Treatment info:
Address of Data Source:
Total ACRES Cleaned Up: .58
Number of Cleanup Jobs Leveraged:
EPA Cleanup Funding:
Leveraged Funding:
Cost Share Funding:
Total Funding:


Top of Page


Climate Adaption and Mitigation - Demolition or Cleanup

There is no data for Climate Adaption and Mitigation - Demolition or Cleanup.


Top of Page


Institutional and Engineering Controls

No
No


Top of Page


Redevelopment and Other Leveraged Accomplishments

There are no current redevelopment activities.


Number of Redevelopment Jobs Leveraged:
Actual Acreage of Greenspace Created:
Leveraged Funding:


Top of Page


Climate Adaption and Mitigation - Redevelopment

There is no data for Climate Adaption and Mitigation – Redevelopment


Top of Page


Additional Property Attributes

The first developed use of the subject property occurred between 1946 with the construction of two office buildings associated with a used car lot. Prior to 1946, the property was vacant land. The former buildings were demolished, and the current building constructed in 1958. The current building was occupied by LaSalle Distributing Company from at least 1961 (likely from construction) until 1980, was occupied by a church between 1983 and 1986 and has been a furniture and antique retail store since 1989.

The following onsite REC has been identified:

A suspect pipe was observed, consistent with vent pipe along the western exterior face of the building. PM was unable to determine through interviews with knowledge site contacts and review of reasonably ascertainable information the use of the pipe. Based on PM's experience, the pipe may be associated with an orphan underground storage tank (UST). The potential exists for orphan USTs to be present and/or for a release to have occurred. The on-site REC vent pipe was later determined to be the vent pipe for an emergency sump pump generator.

The following adjoining and/or nearby REC has been identified:

* The north adjoining property, identified as 20211-20245 Livernois Avenue, has been utilized by former automotive supplier between the late 1950 to early 1970s and chemical manufacturer from at least 1983 until the early to mid-1990s. The historical use and waste management practices associated with the chemical manufacturer are unknown but would have likely consisted of general hazardous substances and/or petroleum products. Based on this information, close proximity to the subject property (approximately 50 feet), the potential exists for a release to have occurred and migrated onto the subject property.

On September 7, 2022, PM completed subsurface investigation activities at the subject property that consisted of advancing two soil borings (SB-1 and SB-2) and collecting two soil samples for laboratory analysis of VOCs and PNAs to assess the off-site REC identified in PM's June 2022 Phase I ESA.

No concentrations of VOCs or PNAs were detected in any of the soil or groundwater samples collected from the subject property above the EGLE GCC and/or laboratory MDLs. Based on the absence of target analytes above the most restrictive Part 201 Residential cleanup criteria in the soil samples collected from the subject property, the subject property does not meet the definition of a "facility" as defined in Section 20101(1)(r) of Part 201, of P.A. 451 of 1994, as amended. Additionally, Parts 201 and 213 of the 1994 Michigan Natural Resources Environmental Protection Act (NREPA) provide liability protection for off-site migration of contamination to the subject property.

PM Environmental (PM), a Pinchin Company, has completed a Pre-Demolition Asbestos Containing Materials (ACM) and Lead-Containing Paint Survey of the Industrial Property located at 20201 Livernois Avenue, Detroit, Michigan.

The results of PM's survey identified the following ACM:

* Mudded Pipe Fittings Associated with Fiberglass Straight Pipe Insulation (HA1) - 42 Each
* Drywall and Joint Compound (HA6)* - 300 Square Feet
* 9" x 9" Off-White Floor Tile (HA10) - 4,950 Square Feet
* Light Heat Shield (HA15) - 6 Square Feet
* Transite Electrical Arc Chute (HA20) - 2 Square Feet
* Interior Door Frame Caulk (HA21) - 238 Square Feet
* 9" x 9" White Floor Tile (HA25) - 100 Square Feet
* 9" x 9" Black Floor Tile (HA27) - 300 Square Feet
* HVAC Fiberglass Duct Insulation with Paper Layer (HA29) - 625 Square Feet
* Remnant Transite Board (HA30) - 5 Square Feet
* Transite Exhaust Pipe (HA31) - 20 Linear Feet
* Woven Expansion Joint Fabric (HA32) - 15 Square Feet

*Although the drywall layer of the Drywall and Joint Compound (HA6), was found to not contain asbestos, PM determined that the drywall and joint compound layers of this material are inseparable. Therefore, the entire material must be t
Industry (.58)